Large Capacity Pass Through Sterilizer PLC Control For Mushroom Cultivation
Specification
1. For a correct sterilization the pressure within the chamber must be at 15 psi for a certain period.
This means it will be about 121 ℃ within the cooker. No organism will stay alive during such a temperature. The duration of sterilization time depends a lot on the ingredients of the substrate and the volume of it. The specific sterilization time of specific substrates are mentioned in the techniques section.
2. PLC fully automatic control system: automatic temperature control, automatic pressure control,
automatic sterilizer time control
3. Safe operation: electric and mechanical double safety interlock protection system for safe operation
4. Overpressure protection: electric and mechanical double overpressure protection system
for safe operation
5. Over temperature protection: electric over temperature protection system
6. Equalized heat distribution: the temperature inside the reactor is equalized distribution, which
means the temperature difference is less than 1.0℃
7. Electrical heating system: the electrical heating tube with the material of stainless steel, one
set reactor with several units of heating tubes to heat the water uniformly and quickly.
8. Humanization design and long life span material: stainless steel material, carbon steel, with
high intelligent automatic control system
Description
1. Mushroom autoclave machine was used the water ring vacuum pumps, vacuum degree
reached less than -0.08 Mpa, at the same time in the process of sterilization, control system,
according to the temperature of the inner chamber of the steam exhaust steam automatic
adjustment.
2. Mushroom autoclave machine was design by rectangular structure, this kind of autoclave
has particular pipeline design and advance control system.
Applications
Widely used in food industry, mushroom sterilization, and other food sterilization field.
Competitive Advantage
This is a stable technique, which has provided good results over the past twenty years. If any
diseases are discovered, the infected bag of mushroom can be simply removed without the
risk of contaminating the rest of the substrate.
Program Parameter
Cycle name | Further details | Application |
Instruments/Tools | 3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. | Solid materials to be sterilized: ●Packaged instruments ●Empty glass containers ●Empty metal containers Porous materials to be sterilized: ●Rubber articles |
Clothing | 3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. | Materials to be sterilized from which air can’t be easily displaced ●Textile |
User Programmable | All preset parameters can be reset; Multiple customized programs can be set and stored by user. | Customized |
Test programs | ||
B-D Test | 3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. | Test program |
Vacuum LeakTest | Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. | Test program |
ZHANGJIAGANG MEDPHARM MACHINERY LTD.
MEDPHARM Company team is committed to providing quality sterilization products, service, parts and
maintenance training at significant savings. From customized parts packages to turnkey equipment
acquisition and installation, our innovative sterilization solutions are designed to meet our customers' needs.
We understand that untimely breakdowns are costly and can be detrimental to your everyday operations.
Our service team is compromised of expert technicians that respond quickly to all of your service needs.
We offer on-site service support including inservices, installation and deinstallation of your equipment. From
breakdown repairs to comprehensive maintenance programs, we have an innovative service solution for you.
We will service on-Site Repairs.Our staff is equipped with the resources required to provide you with
on-site, on-time repairs in compliance with manufacturer specifications. We also provide installation,
deinstallation, and inservices on most makes and models of sterilization equipment. Near or far we can
provide you with service support that you need.
Our reconditioning background has taught us of the importance of having quality parts on hand at all times.
We have a large inventory of individual repair parts, as well as preventive maintenance kits, and consumables
in stock and ready to ship today.
With our expert technical support staff, it is not always necessary to have part numbers to place an order.
We will help you identify the quality parts that you need.