Home /

2-1/2" CA62MM Dust Collector MM Series Manifold Mount Pulse Valve For Reverse

Send your message to this supplier
*From:
Your email address is incorrect!
To:Ningbo Brando Hardware Co., Ltd
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap 2-1/2
  • Buy cheap 2-1/2
  • Buy cheap 2-1/2
  • Buy cheap 2-1/2
  • Buy cheap 2-1/2

2-1/2" CA62MM Dust Collector MM Series Manifold Mount Pulse Valve For Reverse Jet Baghouse Dust Extraction System

Ask Latest Price
Brand Name:Brando
Model Number:CA62MM
Certification:ISO、CE
Payment Terms:L/C, T/T, Western Union
Supply Ability:100000pcs per month
Delivery Time:Negotiation
Price:Negotiation
Company Data
Verified Supplier
Contact Person Brandon Bao
Business Type: Manufacturer Distributor/Wholesaler Exporter Seller
Officials: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China
Quality: Quality Certifitation Available
Visit Website
Product Details Company Profile
Product Details

2-1/2'' CA62MM Dust Collector MM Series Manifold Mount Pulse Valve for Reverse Jet Baghouse Dust Extraction System


This is high performance solenoid pulse valve for pulsing large volumes of air into filter bags for particulate removal.
Valve Body made by diecast aluminum alloy.Durable and safety. Other material can be customized, like Waterproof material, Anti-corrosive material. These series are high-flow pilot valves, pilot valve enclosures and bulkhead fittings that have been specially designed for use in dust collector systems.


Youtube Video About 2-1/2'' Submerged Pulse Valve:


Specification:

Model No.CA62MM
Port Size2-1/2''
Orifice Size62mm
Number of Diaphragm2
MediaAir
Pressure Range0.3~0.8Mpa
Working Temperature-5~+55℃
Seal MaterialNBR(common, all available)
Body MaterialDiecast Aluminum
VoltageAC220V, AC110V, AC24V, DC24V

Special voltages and special specifications, please contant us.


Overall Dimension:

Overall Dimension CA62MM

Details About CA62MM Electromagentic Solenoid Pulse Valve:

Details About CA62MM Electromagentic Solenoid Pulse Valve:


Construction:

Body and Dreeser Nuts: Aluminum (diecast)
Ferrule: 305 Stainless Steel
Armature: 430FR Stainless Steel
Diaphragm and Seals: Nitrile or FKM
Spring: 304 Stainless Steel
Screws: 302 or 304 Stainless steel
Outlet Pipe: Schedule 40 wrought steel zinc passivated
Diaphragm Seat: PA-66 (25 & 40MM standard), Nitrile-coated mild steel (76MM standard), Acetal (102MM standard) or Vitoncoated mild steel


Troubleshooting of Dust Collector System :

Pressure Loss

1. Ensure feed pipes provide adequate flow to the system.
2. Ensure compressed air supply system is able to meet the compressed air demand.
3.Increase pause time between pulses. Or adjust compressor cycle settings
4. Replace using diaphragm repair kit clean internal valve seats determine source of foreign matter and eliminate.
5. Replace component using pilot repair kit
6. Ensure good seals at pilot line connections.
7. Replace pilot lines.
8. Replace component using pilot repair kit clean internal valve seats
9.Check threads if out of specification correct them.
10. remove valve clean off sealant from valve and stub pipe carefully re-apply according to sealant instructions
11. Replace dresser nut seals using dresser nut seal replacement kit.
12. Tighten firmly by hand or with the use of chaingrips or dresser-nut spanner tool.
13. Inspect and replace if necessary. Also ensure sealing surfaces are clean and undamaged.
14. Replace component using pilot repair kit
15. Check that application temperature is within the operating range of the product. Install an appropriate pilot repair kit.
16. Replace valve
17.Replace using diaphragm repair kit.

Pulse Valve Does not Open

1.Increase pulse duration setting
2.Check output voltage and amps meet solenoid requirements
3.Replace with correct pins.
4.inspect and replace/repair.
5.Replace with appropriate size pneumatic tube
6. Relocate pilot valves closer to diaphragm valves and shorten pilot lines.
7.Inspect and replace fittings.


Pulse Valve Does Not Close

1. Inspect and replace with pilot repair kit
2. Ensure that the installation is not affected by stray magnetic fields, replace solenoid
3. Check controller. Reprogram or replace.
4. Replace pilot line.
5. Reconnect
6. Inspect and replace with diaphragm repair kit
7. Inspect and ensure bleed paths are clear


Diaphragm spring failures

1. Replace manifold system with higher volume manifolds to ensure residual pressure is 70% of pre-pulse pressure, OR shorten pulse duration
2. Reduce pipe lengths or increase pipe diameters.
3. Ensure any valves inline with the pulse valves are fully open or removed entirely.
4. Replace manifold system with higher volume manifolds to ensure residual pressure is 70% of pre-pulse pressure. Increase the diameter of connecting pipes to minimum 1.5 x the nominal pulse valve outlet size
5. Clean manifold system, clear bleed paths.
6. Introduce a small restriction to the valve outlet, to assist in developing some backpressure at the valve outlet.
7. Where relevant, replace nitrile diaphragms with the Shockwave molded diaphragm equivalent.


Repair Kits of CA62MM Solenoid Pulse Valve:

Diaphragm Repair Kits of CA62MM Solenoid pulse valve Armature Repair Kits of CA62MM Solenoid Pulse Valve

Model No.Repair KitsIncludes
CA62MMK5004 (M1638A)Diaphragm kits include main and secondary diaphragms and all spring
K5005 (M1639A)
K0380 (M1131B)O-ring, armature assembly, armature spring, ferrule

Focus on your demands, Offer you best solution:

√ Contact us if some points you have doubt

√ Contact us if somewhere need to change

√ Contact us if not the one you are looking for

√ Contact us if you are doing designing


Welcome to your any question and inquiry!

Company Profile

Ningbo Brando Hardware Co., Ltd

* Foucus on your demand, Offer you best solutions as the first mission of Ningbo Brando Hardware Co., Ltd, we work on designing and manufacturing solenoid coils, solenoid armatures and solenoid valves for more than 15 years.

 

* We have served customers from Europe, North America, Middle east, Southeast Asian by designing and manufacturing for their automation fluid control applications, related to industries of pneumatic automation equipment, food beverage dispenser, agricultural irrigation, printing and dyeing, dust collector, home appliance, automobile, textile, refrigeration, etc.

 

Since the company's inception, we are dedicated to providing high quality products and service to our customers. With focusing on our customers' demands, at before production we discuss technical points according to applications with customers to reduce mistake and save cost for both sides. During production, we use high precision CNC machine, machining center to control dimensions and improve productivity. At beginning and mid of machining, our senior inspectors check quality regularly by recording data on documents as per ISO9001 management system. Before shipment, our staff make testing and complete inspection one piece by one piece to ensure the products without defect when reached our customer's hands.

 

Ningbo Brando Hardware Co., Ltd will offer you best service with fast response, let's make the fluid control application more widely and smartly.

 

 

Product Categories:

1. Solenoid Valve
2. Solenoid Coil
3. Solenoid Armature
4. Solenoid Coil Connector
5. Solenoid Valve Timer
6. Pulse Valve
7. Valve Diaphragm
8. Pulse Controller
9. Refrigeration Valve
10. Pneumatic Valve
11. Pneumatic Fitting
12. Pneumatic Cylinder
13. Pneumatic Filter Regulator Lubricator
14. Pneumatic Vibrator
15. Ball Valve
16. Butterfly Valve
15. and so on

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Ningbo Brando Hardware Co., Ltd

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China Aluminum SS30 3 / 4 Inch Port Pulse Jet Solenoid Valve Z Type SCG353A043 wholesale

Aluminum SS30 3 / 4 Inch Port Pulse Jet Solenoid Valve Z Type SCG353A043

China Normally Close Threaded Ports Pneumatic Pulse Valve Similar As CA45T RCA45T wholesale

Normally Close Threaded Ports Pneumatic Pulse Valve Similar As CA45T RCA45T

China CA76MM 220V AC 50/60HZ Pneumatic Pulse Valve , Dust Collector Pneumatic Diaphragm Valve wholesale

CA76MM 220V AC 50/60HZ Pneumatic Pulse Valve , Dust Collector Pneumatic Diaphragm Valve

China Right Angle Aluminium Pneumatic Pulse Valve CA50T QR DIN43650A SS304 Ferrule wholesale

Right Angle Aluminium Pneumatic Pulse Valve CA50T QR DIN43650A SS304 Ferrule

China 220V AC 24V DC DN20 3/4 Inch CA20T Normally Closed Right Angle Diaphragm Dust Collector Pulse Valve wholesale

220V AC 24V DC DN20 3/4 Inch CA20T Normally Closed Right Angle Diaphragm Dust Collector Pulse Valve

China SCG353A051 - G2 1/2 Orifice Size 62mm Threaded Series 353 Dust Collector Dual Pulse Valves Integral Dual Stage wholesale

SCG353A051 - G2 1/2 Orifice Size 62mm Threaded Series 353 Dust Collector Dual Pulse Valves Integral Dual Stage

China SCG353A043 - G3/4 Orifice Size 20mm Threaded Dust Collector Pulse Valves Aluminium Body NBR Seal Series 353 wholesale

SCG353A043 - G3/4 Orifice Size 20mm Threaded Dust Collector Pulse Valves Aluminium Body NBR Seal Series 353

China RCA45FS GOYEN Type 1.5'' Flanged Remote Pilot Pulse Valve For Dust Collector wholesale

RCA45FS GOYEN Type 1.5'' Flanged Remote Pilot Pulse Valve For Dust Collector

China 2'' Manifold Flat Mount Full Immersion Pulse Jet Valve For Dust Collector 24V 220V wholesale

2'' Manifold Flat Mount Full Immersion Pulse Jet Valve For Dust Collector 24V 220V

China 3-8V5 Goyen Type Solenoid Pilot Valve Enclosure Box RCA3-8V5 220V 110V 24V wholesale

3-8V5 Goyen Type Solenoid Pilot Valve Enclosure Box RCA3-8V5 220V 110V 24V

China 1'' RCA25T Goyen Type Remote Control Valve For Dust Collector wholesale

1'' RCA25T Goyen Type Remote Control Valve For Dust Collector

Inquiry Cart 0